<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<?xml-stylesheet type="text/xsl" href="ViewNLM-v2.3.xsl"?>
<article xml:lang="KO" article-type="research-article">

<front>
<journal-meta>
<journal-id journal-id-type="nlm-ta">J Korean Orthop Assoc</journal-id>
<journal-id journal-id-type="publisher-id">JKOA</journal-id>
<journal-title>Journal of the Korean Orthopaedic Association</journal-title>
<issn pub-type="ppub">1226-2102</issn>
<publisher>
<publisher-name>The Korean Orthopaedic Association</publisher-name>
</publisher>
</journal-meta>

<article-meta>
<article-id pub-id-type="doi">10.4055/jkoa.2007.42.5.593</article-id>
<article-categories>
<subj-group>
<subject>Original Article</subject>
</subj-group>
</article-categories>
<title-group>
<article-title>The Validity and Reliability of the EMC Device; For the Checking of the Mobility of the First Ray of the Foot</article-title>
</title-group>

<contrib-group>

<contrib contrib-type="author">
<name>
<surname>Kim</surname>
<given-names>J-Young</given-names>
</name>
<degrees>M.D.</degrees>
<xref ref-type="aff" rid="A1"></xref>
</contrib>

<contrib contrib-type="author">
<name>
<surname>Lee</surname>
<given-names>Kyung Tai</given-names>
</name>
<degrees>M.D.</degrees>
<xref ref-type="aff" rid="A1"></xref>
</contrib>

<contrib contrib-type="author">
<name>
<surname>Young</surname>
<given-names>Ki Won</given-names>
</name>
<degrees>M.D.</degrees>
<xref ref-type="aff" rid="A1"></xref>
</contrib>

<contrib contrib-type="author">
<name>
<surname>Park</surname>
<given-names>Ye Soo</given-names>
</name>
<degrees> M.D.</degrees>
<xref ref-type="aff" rid="A2">&#x002A;</xref>
</contrib>

<contrib contrib-type="author">
<name>
<surname>Jeong</surname>
<given-names>Ju Seon</given-names>
</name>
<degrees>M.D.</degrees>
<xref ref-type="aff" rid="A1"></xref>
</contrib>

<contrib contrib-type="author" corresp="yes">
<name>
<surname>Hwang</surname>
<given-names>Seung Keun</given-names>
</name>
<degrees>M.D.</degrees>
<xref ref-type="aff" rid="A1"></xref>
</contrib>

</contrib-group>

<aff id="A1">Department of Orthopedic Surgery, Eulji General Hospital, Eulji University, Seoul, Korea.</aff>
<aff id="A2"><label>&#x002A;</label>Department of Orthopedic Surgery, College of Medicine, Hanyang University, Seoul, Korea.</aff>

<author-notes>
<corresp>Address reprint requests to Seung Keun Hwang, M.D. Department of Orthopedic Surgery, Eulji General Hospital, Eulji University, 280-1, Hagye-dong, Nowon-gu, Seoul 139-711, Korea. Tel: +82.2-970-8036, Fax: +82.2-973-3024, <email>seungkeunh@hotmail.com</email></corresp>
</author-notes>

<pub-date pub-type="ppub">
<month>10</month>
<year>2007</year>
</pub-date>
<pub-date pub-type="epub">
<day>31</day>
<month>10</month>
<year>2007</year>
</pub-date>
<volume>42</volume>
<issue>5</issue>
<fpage>593</fpage>
<lpage>598</lpage>


<permissions>
<copyright-statement>Copyright &#x00A9; 2007 The Korean Orthopaedic Association</copyright-statement>
<copyright-year>2007</copyright-year>
</permissions>

<abstract>
<sec>
<title>Purpose</title>
<p>To evaluate the validity and intra-rater, inter-rater reliability of the EMC device used to check the mobility of the first ray of the foot.</p>
</sec>
<sec>
<title>Materials and Methods</title>
<p>Sixty-nine cases (43 patients) of mild to severe hallux valgus feet were enrolled in this study. For an analysis of the validity of the EMC device, the dorsal mobility of the first ray of the foot was measured using the modified Coleman block test and EMC device. The intra- and inter-rater reliability of EMC device was evaluated by measuring the dorsal mobility of the first ray of the foot twice with three independent raters blinded to other's results. The results were analyzed for the intra-rater reliability and for inter-rater reliability.</p>
</sec>
<sec>
<title>Results</title>
<p>The mean value of the dorsal mobility of the first ray of the foot by the EMC device and modified Coleman block test was 8.3 mm (range; 4.3-12.3 mm) and 7.4 mm (range; 3.4-10.3 mm), respectively. There was a significant difference between the EMC device and modified Coleman block test (p&#x003C;0.05). However, both the measured data, showed a good correlation (Pearson correlation coefficient=0.84). The paired t-test for intra-rater reliability and ANOVA testing for inter-rater reliability showed no statistically significant difference.</p>
</sec>
<sec>
<title>Conclusion</title>
<p>The EMC device is reliable and valid for measuring the mobility of the first ray of the foot.</p>
</sec>
</abstract>

<kwd-group>
<kwd>Mobility of the first ray</kwd>
<kwd>EMC device</kwd>
<kwd>Validity and reliability</kwd>
</kwd-group>
</article-meta>
</front>


<back>


    <ref-list>

  <ref id="B1">
    <label>1</label>
    <nlm-citation citation-type="journal">
      <person-group person-group-type="author">
        <name>
          <surname>Bednarz</surname>
          <given-names>PA</given-names>
        </name>
        <name>
          <surname>Manoli</surname>
          <given-names>A</given-names>
          <suffix>2nd</suffix>
        </name>
      </person-group>
      <article-title>Modified Lapidus procedure for the treatment of hypermobile hallux valgus</article-title>
      <source>Foot Ankle Int</source>
      <year>2000</year>
      <volume>21</volume>
      <fpage>816</fpage>
      <lpage>821</lpage>
    </nlm-citation>
  </ref>
 
  <ref id="B2">
    <label>2</label>
    <nlm-citation citation-type="book">
      <person-group person-group-type="author">
        <name>
          <surname>Coughlin</surname>
          <given-names>MJ</given-names>
        </name>
        <name>
          <surname>Mann</surname>
          <given-names>RA</given-names>
        </name>
      </person-group>
      <source>Surgery of the foot and ankle</source>
      <year>1999</year>
      <edition>7th ed</edition>
      <publisher-loc>St. Louis</publisher-loc>
      <publisher-name>Mosby</publisher-name>
      <fpage>168</fpage>
      <lpage>170</lpage>
    </nlm-citation>
  </ref>

  <ref id="B3">
    <label>3</label>
    <nlm-citation citation-type="journal">
      <person-group person-group-type="author">
        <name>
          <surname>Faber</surname>
          <given-names>FW</given-names>
        </name>
        <name>
          <surname>Kleinrensink</surname>
          <given-names>GJ</given-names>
        </name>
        <name>
          <surname>Verhoog</surname>
          <given-names>MW</given-names>
        </name>
        <etal/>
      </person-group>
      <article-title>Mobility of the first tarsometatarsal joint in relation to hallux valgus deformity: anatomical and biomechanical aspects</article-title>
      <source>Foot Ankle Int</source>
      <year>1999</year>
      <volume>20</volume>
      <fpage>651</fpage>
      <lpage>656</lpage>
    </nlm-citation>
  </ref>

  <ref id="B4">
    <label>4</label>
    <nlm-citation citation-type="journal">
      <person-group person-group-type="author">
        <name>
          <surname>Fritz</surname>
          <given-names>GR</given-names>
        </name>
        <name>
          <surname>Prieskorn</surname>
          <given-names>D</given-names>
        </name>
      </person-group>
      <article-title>First metatarsocuneiform motion: a radiographic and statistical analysis</article-title>
      <source>Foot Ankle Int</source>
      <year>1995</year>
      <volume>16</volume>
      <fpage>117</fpage>
      <lpage>123</lpage>
    </nlm-citation>
  </ref>

  <ref id="B5">
    <label>5</label>
    <nlm-citation citation-type="journal">
      <person-group person-group-type="author">
        <name>
          <surname>Glasoe</surname>
          <given-names>WM</given-names>
        </name>
        <name>
          <surname>Allen</surname>
          <given-names>MK</given-names>
        </name>
        <name>
          <surname>Saltzman</surname>
          <given-names>CL</given-names>
        </name>
        <name>
          <surname>Ludewig</surname>
          <given-names>PM</given-names>
        </name>
        <name>
          <surname>Sublett</surname>
          <given-names>SH</given-names>
        </name>
      </person-group>
      <article-title>Comparison of two methods used to assess first-ray mobility</article-title>
      <source>Foot Ankle Int</source>
      <year>2002</year>
      <volume>23</volume>
      <fpage>248</fpage>
      <lpage>252</lpage>
    </nlm-citation>
  </ref>

  <ref id="B6">
    <label>6</label>
    <nlm-citation citation-type="journal">
      <person-group person-group-type="author">
        <name>
          <surname>Glasoe</surname>
          <given-names>WM</given-names>
        </name>
        <name>
          <surname>Allen</surname>
          <given-names>MK</given-names>
        </name>
        <name>
          <surname>Yack</surname>
          <given-names>HJ</given-names>
        </name>
      </person-group>
      <article-title>Measurement of dorsal mobility in the first ray: elimination of fat pad compression as a variable</article-title>
      <source>Foot Ankle Int</source>
      <year>1998</year>
      <volume>19</volume>
      <fpage>542</fpage>
      <lpage>546</lpage>
    </nlm-citation>
  </ref>

  <ref id="B7">
    <label>7</label>
    <nlm-citation citation-type="journal">
      <person-group person-group-type="author">
        <name>
          <surname>Glasoe</surname>
          <given-names>WM</given-names>
        </name>
        <name>
          <surname>Yack</surname>
          <given-names>HJ</given-names>
        </name>
        <name>
          <surname>Saltzman</surname>
          <given-names>CL</given-names>
        </name>
      </person-group>
      <article-title>Measuring first ray mobility with a new device</article-title>
      <source>Arch Phys Med Rehabil</source>
      <year>1999</year>
      <volume>80</volume>
      <fpage>122</fpage>
      <lpage>124</lpage>
    </nlm-citation>
  </ref>

  <ref id="B8">
    <label>8</label>
    <nlm-citation citation-type="journal">
      <person-group person-group-type="author">
        <name>
          <surname>Glasoe</surname>
          <given-names>WM</given-names>
        </name>
        <name>
          <surname>Yack</surname>
          <given-names>HJ</given-names>
        </name>
        <name>
          <surname>Saltzman</surname>
          <given-names>CL</given-names>
        </name>
      </person-group>
      <article-title>The reliability and validity of a first ray measurement device</article-title>
      <source>Foot Ankle Int</source>
      <year>2000</year>
      <volume>21</volume>
      <fpage>240</fpage>
      <lpage>246</lpage>
    </nlm-citation>
  </ref>

  <ref id="B9">
    <label>9</label>
    <nlm-citation citation-type="journal">
      <person-group person-group-type="author">
        <name>
          <surname>Grebing</surname>
          <given-names>BR</given-names>
        </name>
        <name>
          <surname>Coughlin</surname>
          <given-names>MJ</given-names>
        </name>
      </person-group>
      <article-title>The effect of ankle position on the exam for first ray mobility</article-title>
      <source>Foot Ankle Int</source>
      <year>2004</year>
      <volume>25</volume>
      <fpage>467</fpage>
      <lpage>475</lpage>
    </nlm-citation>
  </ref>

  <ref id="B10">
    <label>10</label>
    <nlm-citation citation-type="journal">
      <person-group person-group-type="author">
        <name>
          <surname>Jones</surname>
          <given-names>CP</given-names>
        </name>
        <name>
          <surname>Coughlin</surname>
          <given-names>MJ</given-names>
        </name>
        <name>
          <surname>Pierce-Villadot</surname>
          <given-names>R</given-names>
        </name>
        <etal/>
      </person-group>
      <article-title>The validity and reliability of the Klaue device</article-title>
      <source>Foot Ankle Int</source>
      <year>2005</year>
      <volume>26</volume>
      <fpage>951</fpage>
      <lpage>956</lpage>
    </nlm-citation>
  </ref>

  <ref id="B11">
    <label>11</label>
    <nlm-citation citation-type="journal">
      <person-group person-group-type="author">
        <name>
          <surname>Klaue</surname>
          <given-names>K</given-names>
        </name>
        <name>
          <surname>Hansen</surname>
          <given-names>ST</given-names>
        </name>
        <name>
          <surname>Masquelet</surname>
          <given-names>AC</given-names>
        </name>
      </person-group>
      <article-title>Clinical, quantitative assessment of first tarsometatarsal mobility in the sagittal plane and its relation to hallux valgus deformity</article-title>
      <source>Foot Ankle Int</source>
      <year>1994</year>
      <volume>15</volume>
      <fpage>9</fpage>
      <lpage>13</lpage>
    </nlm-citation>
  </ref>

  <ref id="B12">
    <label>12</label>
    <nlm-citation citation-type="journal">
      <person-group person-group-type="author">
        <name>
          <surname>Lee</surname>
          <given-names>KT</given-names>
        </name>
        <name>
          <surname>Young</surname>
          <given-names>K</given-names>
        </name>
      </person-group>
      <article-title>Measurement of first-ray mobility in normal vs. hallux valgus patients</article-title>
      <source>Foot Ankle Int</source>
      <year>2001</year>
      <volume>22</volume>
      <fpage>960</fpage>
      <lpage>964</lpage>
    </nlm-citation>
  </ref>

  <ref id="B13">
    <label>13</label>
    <nlm-citation citation-type="journal">
      <person-group person-group-type="author">
        <name>
          <surname>Myerson</surname>
          <given-names>M</given-names>
        </name>
      </person-group>
      <article-title>Metatarsocuneiform arthrodesis for treatment of hallux valgus and metatarsus primus varus</article-title>
      <source>Orthopedics</source>
      <year>1990</year>
      <volume>13</volume>
      <fpage>1025</fpage>
      <lpage>1031</lpage>
    </nlm-citation>
  </ref>

  <ref id="B14">
    <label>14</label>
    <nlm-citation citation-type="journal">
      <person-group person-group-type="author">
        <name>
          <surname>Myerson</surname>
          <given-names>M</given-names>
        </name>
        <name>
          <surname>Allon</surname>
          <given-names>S</given-names>
        </name>
        <name>
          <surname>McGarvey</surname>
          <given-names>W</given-names>
        </name>
      </person-group>
      <article-title>Metatarsocuneiform arthrodesis for management of hallux valgus and metatarsus primus varus</article-title>
      <source>Foot Ankle</source>
      <year>1992</year>
      <volume>13</volume>
      <fpage>107</fpage>
      <lpage>115</lpage>
    </nlm-citation>
  </ref>

  <ref id="B15">
    <label>15</label>
    <nlm-citation citation-type="journal">
      <person-group person-group-type="author">
        <name>
          <surname>Myerson</surname>
          <given-names>MS</given-names>
        </name>
        <name>
          <surname>Badekas</surname>
          <given-names>A</given-names>
        </name>
      </person-group>
      <article-title>Hypermobility of the first ray</article-title>
      <source>Foot Ankle Clin</source>
      <year>2000</year>
      <volume>5</volume>
      <fpage>469</fpage>
      <lpage>484</lpage>
    </nlm-citation>
  </ref>

  <ref id="B16">
    <label>16</label>
    <nlm-citation citation-type="journal">
      <person-group person-group-type="author">
        <name>
          <surname>Prieskorn</surname>
          <given-names>DW</given-names>
        </name>
        <name>
          <surname>Mann</surname>
          <given-names>RA</given-names>
        </name>
        <name>
          <surname>Fritz</surname>
          <given-names>G</given-names>
        </name>
      </person-group>
      <article-title>Radiographic assessment of the second metatarsal: measure of first ray hypermobility</article-title>
      <source>Foot Ankle Int</source>
      <year>1996</year>
      <volume>17</volume>
      <fpage>331</fpage>
      <lpage>333</lpage>
    </nlm-citation>
  </ref>

  <ref id="B17">
    <label>17</label>
    <nlm-citation citation-type="journal">
      <person-group person-group-type="author">
        <name>
          <surname>Sangeorzan</surname>
          <given-names>BJ</given-names>
        </name>
        <name>
          <surname>Hansen</surname>
          <given-names>ST</given-names>
          <suffix>Jr</suffix>
        </name>
      </person-group>
      <article-title>Modified Lapidus procedure for hallux valgus</article-title>
      <source>Foot Ankle</source>
      <year>1989</year>
      <volume>9</volume>
      <fpage>262</fpage>
      <lpage>266</lpage>
    </nlm-citation>
  </ref>

  <ref id="B18">
    <label>18</label>
    <nlm-citation citation-type="journal">
      <person-group person-group-type="author">
        <name>
          <surname>Shirk</surname>
          <given-names>C</given-names>
        </name>
        <name>
          <surname>Sandrey</surname>
          <given-names>MA</given-names>
        </name>
        <name>
          <surname>Erickson</surname>
          <given-names>M</given-names>
        </name>
      </person-group>
      <article-title>Reliability of first ray position and mobility measurements in experienced and inexperienced examiners</article-title>
      <source>J Athl Train</source>
      <year>2006</year>
      <volume>41</volume>
      <fpage>93</fpage>
      <lpage>99</lpage>
    </nlm-citation>
  </ref>

  <ref id="B19">
    <label>19</label>
    <nlm-citation citation-type="journal">
      <person-group person-group-type="author">
        <name>
          <surname>Smith</surname>
          <given-names>RW</given-names>
        </name>
        <name>
          <surname>Reynolds</surname>
          <given-names>JC</given-names>
        </name>
        <name>
          <surname>Stewart</surname>
          <given-names>MJ</given-names>
        </name>
      </person-group>
      <article-title>Hallux valgus assessment; report of research committee of American Orthopaedic Foot and Ankle Society</article-title>
      <source>Foot Ankle</source>
      <year>1984</year>
      <volume>5</volume>
      <fpage>92</fpage>
      <lpage>103</lpage>
    </nlm-citation>
  </ref>

  <ref id="B20">
    <label>20</label>
    <nlm-citation citation-type="journal">
      <person-group person-group-type="author">
        <name>
          <surname>Voellmicke</surname>
          <given-names>KV</given-names>
        </name>
        <name>
          <surname>Deland</surname>
          <given-names>JT</given-names>
        </name>
      </person-group>
      <article-title>Manual examination technique to assess dorsal instability of the first ray</article-title>
      <source>Foot Ankle Int</source>
      <year>2002</year>
      <volume>23</volume>
      <fpage>1040</fpage>
      <lpage>1041</lpage>
    </nlm-citation>
  </ref>

    </ref-list>

</back>

<floats-wrap>

<fig position="float" id="F1">
<label>Fig. 1</label>
<caption>
  <p>The dorsal mobility of the first ray of the foot was measured using the modified Coleman block test.</p>
</caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="jkoa-42-593-g001" alt-version="no"></graphic>
</fig>

<fig position="float" id="F2">
<label>Fig. 2</label>
<caption>
  <p>The scatter plot shows measured data with the EMC device and the calculated data with the lateral radiographs using the modified Coleman block test.</p>
</caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="jkoa-42-593-g002" alt-version="no"></graphic>
</fig>

<table-wrap position="float" id="T1">
<label>Table 1</label>
<caption>
  <p>Comparison of the Mean and Standard Deviation of the 1<sup>st</sup> Ray Dorsal Mobility of the Foot between the EMC Device and Modified Coleman Block Test</p>
</caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="jkoa-42-593-i001" alt-version="no"></graphic>
<table-wrap-foot>
<fn>
  <p><sup>&#x002A;</sup>, standard deviation.</p>
</fn>
</table-wrap-foot>
</table-wrap>

<table-wrap position="float" id="T2">
<label>Table 2</label>
<caption>
  <p>Mean and Standard Deviation of the 1<sup>st</sup> Ray Dorsal Mobility of the Foot For Intra-rater</p>
</caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="jkoa-42-593-i002" alt-version="no"></graphic>
<table-wrap-foot>
<fn>
  <p><sup>&#x002A;</sup>, standard deviation.</p>
</fn>
</table-wrap-foot>
</table-wrap>

<table-wrap position="float" id="T3">
<label>Table 3</label>
<caption>
  <p>Mean and Standard Deviation of the 1<sup>st</sup> Ray Dorsal Mobility of the Foot For Inter-rater</p>
</caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="jkoa-42-593-i003" alt-version="no"></graphic>
<table-wrap-foot>
<fn>
  <p><sup>&#x002A;</sup>, standard deviation</p>
</fn>
</table-wrap-foot>
</table-wrap>

</floats-wrap>

</article>