<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.1 20151215//EN" "JATS-journalpublishing1.dtd">
<article xml:lang="KO" article-type="research-article">

<front>
<journal-meta>
<journal-id journal-id-type="nlm-ta">J Korean Ophthalmol Soc</journal-id>
<journal-id journal-id-type="publisher-id">JKOS</journal-id>
<journal-title-group>
<journal-title>Journal of the Korean Ophthalmological Society</journal-title>
</journal-title-group>
<issn pub-type="ppub">0378-6471</issn>
<issn pub-type="epub">2092-9374</issn>
<publisher>
<publisher-name>The Korean Ophthalmological Society</publisher-name>
</publisher>
</journal-meta>

<article-meta>
<article-id pub-id-type="doi">10.3341/jkos.2017.58.10.1160</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Original Article</subject>
</subj-group>
</article-categories>
<title-group>
<article-title>Retinal Nerve Fiber Layer Thickness Measurement Using Swept Source Optical Coherence Tomography in Healthy Korean</article-title>
</title-group>

<contrib-group>

<contrib contrib-type="author">
<name>
<surname>Choi</surname>
<given-names>Soon Ho</given-names>
</name>
<degrees>MD</degrees>
<xref ref-type="aff" rid="A1">1</xref>
</contrib>

<contrib contrib-type="author">
<name>
<surname>Ohn</surname>
<given-names>Young-Hoon</given-names>
</name>
<degrees>MD</degrees>
<degrees>PhD</degrees>
<xref ref-type="aff" rid="A2">2</xref>
</contrib>

<contrib contrib-type="author" corresp="yes">
<name>
<surname>Park</surname>
<given-names>Ka Hee</given-names>
</name>
<degrees>MD</degrees>
<xref ref-type="aff" rid="A2">2</xref>
</contrib>

</contrib-group>

<aff id="A1"><label>1</label>Department of Ophthalmology, Seoul Hospital, Soonchunhyang University College of Medicine, Seoul, Korea.</aff>
<aff id="A2"><label>2</label>Department of Ophthalmology, Bucheon Hospital, Soonchunhyang University College of Medicine, Bucheon, Korea.</aff>

<author-notes>
<corresp>Address reprint requests to Ka Hee Park, MD. Department of Ophthalmology, Soonchunhyang University Bucheon Hospital, #170 Jomaru-ro, Bucheon 14584, Korea. Tel: 82-32-621-5053, Fax: 82-32-621-5435, <email>ophkh@schmc.ac.kr</email></corresp>
</author-notes>

<pub-date pub-type="ppub">
<month>10</month>
<year>2017</year>
</pub-date>
<pub-date pub-type="epub">
<day>11</day>
<month>10</month>
<year>2017</year>
</pub-date>
<volume>58</volume>
<issue>10</issue>
<fpage>1160</fpage>
<lpage>1168</lpage>

<history>
<date date-type="received">
<day>23</day>
<month>03</month>
<year>2017</year>
</date>
<date date-type="rev-recd">
<day>14</day>
<month>08</month>
<year>2017</year>
</date>
<date date-type="accepted">
<day>25</day>
<month>09</month>
<year>2017</year>
</date>
</history>

<permissions>
<copyright-statement>&#x00A9;2017 The Korean Ophthalmological Society</copyright-statement>
<copyright-year>2017</copyright-year>
<copyright-holder>The Korean Ophthalmological Society</copyright-holder>
<license license-type="open-access" xlink:href="http://creativecommons.org/licenses/by-nc/3.0/">
<license-p>This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (<ext-link ext-link-type="uri" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="http://creativecommons.org/licenses/by-nc/3.0/">http://creativecommons.org/licenses/by-nc/3.0/</ext-link>) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.</license-p>
</license>
</permissions>

<abstract>
<sec>
<title>Purpose</title>
<p>To investigate retinal nerve fiber layer (RNFL) thickness using swept source (SS)-optical coherence tomography (OCT) in healthy Koreans and to evaluate the effects of age on the distributional variability of thickness.</p>
</sec>
<sec>
<title>Methods</title>
<p>We performed a retrospective review of 309 normal eyes presenting for examination of peripapillary nerve fiber layer thickness measured by SS-OCT (DRI OCT-1, Atlantis SS-OCT, Topcon, Tokyo, Japan) from July 2014 to February 2016. The patients were between the ages of 20 and 79 without systemic or ocular disease. The patients were divided into 3 age groups of 20 to 39 years (85 eyes), 40 to 59 years (140 eyes), and 60 to 79 years (84 eyes). The groups were matched based on average RNFL thickness and quadrant and 12 o'clock position RNFL thickness.</p>
</sec>
<sec>
<title>Results</title>
<p>The average RNFL thickness of the inferior quadrant was the thickest of the layers and revealed a bimodal distribution. In the three groups, the thicknesses of the average RNFL, quadrant, and 12 o'clock RNFL decreased with age. There was significant difference in the measurements (<italic>p</italic> &#x003C; 0.05) of quadrant RNFL thickness except that in the nasal quadrant (<italic>p</italic> = 0.068).</p>
</sec>
<sec>
<title>Conclusions</title>
<p>The thickness of the circumpapillary retinal nerve fiber layer measured by SS-OCT differs according to age and analysis of normal values by age can be useful in the diagnosis of disease.</p>
</sec>
</abstract>

<kwd-group>
<kwd>Korean</kwd>
<kwd>Retinal nerve fiber layer thickness</kwd>
<kwd>Swept source optical coherence tomography</kwd>
</kwd-group>

</article-meta>
</front>

<back>

<fn-group>
<fn fn-type="conflict">
<label>Conflicts of Interest</label>
  <p>The authors have no conflicts to disclose.</p>
</fn>
</fn-group>

<ref-list>
  <ref id="B1">
    <label>1</label>
    <element-citation publication-type="journal">
      <person-group person-group-type="author">
        <name>
          <surname>Banister</surname>
          <given-names>K</given-names>
        </name>
        <name>
          <surname>Boachie</surname>
          <given-names>C</given-names>
        </name>
        <name>
          <surname>Bourne</surname>
          <given-names>R</given-names>
        </name>
        <etal/>
      </person-group>
      <article-title>Can automated imaging for optic disc and retinal nerve fiber layer analysis aid glaucoma detection?</article-title>
      <source>Ophthalmology</source>
      <year>2016</year>
      <volume>123</volume>
      <fpage>930</fpage>
      <lpage>938</lpage>
    </element-citation>
  </ref>

  <ref id="B2">
    <label>2</label>
    <element-citation publication-type="journal">
      <person-group person-group-type="author">
        <name>
          <surname>Reus</surname>
          <given-names>NJ</given-names>
        </name>
        <name>
          <surname>Lemij</surname>
          <given-names>HG</given-names>
        </name>
        <name>
          <surname>Garway-Heath</surname>
          <given-names>DF</given-names>
        </name>
        <etal/>
      </person-group>
      <article-title>Clinical assessment of stereoscopic optic disc photographs for glaucoma: the European Optic Disc Assessment Trial</article-title>
      <source>Ophthalmology</source>
      <year>2010</year>
      <volume>117</volume>
      <fpage>717</fpage>
      <lpage>723</lpage>
    </element-citation>
  </ref>

  <ref id="B3">
    <label>3</label>
    <element-citation publication-type="journal">
      <person-group person-group-type="author">
        <name>
          <surname>Quigley</surname>
          <given-names>HA</given-names>
        </name>
        <name>
          <surname>Dunkelberger</surname>
          <given-names>GR</given-names>
        </name>
        <name>
          <surname>Green</surname>
          <given-names>WR</given-names>
        </name>
      </person-group>
      <article-title>Retinal ganglion cell atrophy correlated with automated perimetry in human eyes with glaucoma</article-title>
      <source>Am J Ophthalmol</source>
      <year>1989</year>
      <volume>107</volume>
      <fpage>453</fpage>
      <lpage>464</lpage>
    </element-citation>
  </ref>

  <ref id="B4">
    <label>4</label>
    <element-citation publication-type="journal">
      <person-group person-group-type="author">
        <name>
          <surname>Sihota</surname>
          <given-names>R</given-names>
        </name>
        <name>
          <surname>Sony</surname>
          <given-names>P</given-names>
        </name>
        <name>
          <surname>Gupta</surname>
          <given-names>V</given-names>
        </name>
        <etal/>
      </person-group>
      <article-title>Diagnostic capability of optical coherence tomography in evaluating the degree of glaucomatous retinal nerve fiber damage</article-title>
      <source>Invest Ophthalmol Vis Sci</source>
      <year>2006</year>
      <volume>47</volume>
      <fpage>2006</fpage>
      <lpage>2010</lpage>
    </element-citation>
  </ref>

  <ref id="B5">
    <label>5</label>
    <element-citation publication-type="journal">
      <person-group person-group-type="author">
        <name>
          <surname>Kampougeris</surname>
          <given-names>G</given-names>
        </name>
        <name>
          <surname>Spyropoulos</surname>
          <given-names>D</given-names>
        </name>
        <name>
          <surname>Mitropoulou</surname>
          <given-names>A</given-names>
        </name>
        <etal/>
      </person-group>
      <article-title>Peripapillary retinal nerve fibre layer thickness measurement with SD-OCT in normal and glaucomatous eyes: distribution and correlation with age</article-title>
      <source>Int J Ophthalmol</source>
      <year>2013</year>
      <volume>6</volume>
      <fpage>662</fpage>
      <lpage>665</lpage>
    </element-citation>
  </ref>

  <ref id="B6">
    <label>6</label>
    <element-citation publication-type="journal">
      <person-group person-group-type="author">
        <name>
          <surname>Hong</surname>
          <given-names>S</given-names>
        </name>
        <name>
          <surname>Seong</surname>
          <given-names>GJ</given-names>
        </name>
        <name>
          <surname>Kim</surname>
          <given-names>SS</given-names>
        </name>
        <etal/>
      </person-group>
      <article-title>Comparison of peripapillary retinal nerve fiber layer thickness measured by spectral vs. time domain optical coherence tomography</article-title>
      <source>Curr Eye Res</source>
      <year>2011</year>
      <volume>36</volume>
      <fpage>125</fpage>
      <lpage>134</lpage>
    </element-citation>
  </ref>

  <ref id="B7">
    <label>7</label>
    <element-citation publication-type="journal">
      <person-group person-group-type="author">
        <name>
          <surname>Yang</surname>
          <given-names>Z</given-names>
        </name>
        <name>
          <surname>Tatham</surname>
          <given-names>AJ</given-names>
        </name>
        <name>
          <surname>Zangwill</surname>
          <given-names>LM</given-names>
        </name>
        <etal/>
      </person-group>
      <article-title>Diagnostic ability of retinal nerve fiber layer imaging by swept-source optical coherence tomography in glaucoma</article-title>
      <source>Am J Ophthalmol</source>
      <year>2015</year>
      <volume>159</volume>
      <fpage>193</fpage>
      <lpage>201</lpage>
    </element-citation>
  </ref>

  <ref id="B8">
    <label>8</label>
    <element-citation publication-type="journal">
      <person-group person-group-type="author">
        <name>
          <surname>Ha</surname>
          <given-names>A</given-names>
        </name>
        <name>
          <surname>Lee</surname>
          <given-names>SH</given-names>
        </name>
        <name>
          <surname>Lee</surname>
          <given-names>EJ</given-names>
        </name>
        <name>
          <surname>Kim</surname>
          <given-names>TW</given-names>
        </name>
      </person-group>
      <article-title>Retinal nerve fiber layer thickness measurement comparison using spectral domain and swept source optical coherence tomography</article-title>
      <source>Korean J Ophthalmol</source>
      <year>2016</year>
      <volume>30</volume>
      <fpage>140</fpage>
      <lpage>147</lpage>
    </element-citation>
  </ref>

  <ref id="B9">
    <label>9</label>
    <element-citation publication-type="journal">
      <person-group person-group-type="author">
        <name>
          <surname>Leem</surname>
          <given-names>HS</given-names>
        </name>
        <name>
          <surname>Paik</surname>
          <given-names>DJ</given-names>
        </name>
        <name>
          <surname>Kim</surname>
          <given-names>HC</given-names>
        </name>
      </person-group>
      <article-title>Morphological analysis of papillary retinal vessels and retinal nerve fiber layer in Koreans</article-title>
      <source>J Korean Ophthalmol Soc</source>
      <year>2007</year>
      <volume>48</volume>
      <fpage>1369</fpage>
      <lpage>1378</lpage>
    </element-citation>
  </ref>

  <ref id="B10">
    <label>10</label>
    <element-citation publication-type="journal">
      <person-group person-group-type="author">
        <name>
          <surname>Lee</surname>
          <given-names>JH</given-names>
        </name>
        <name>
          <surname>Ahn</surname>
          <given-names>CS</given-names>
        </name>
        <name>
          <surname>Lee</surname>
          <given-names>DY</given-names>
        </name>
      </person-group>
      <article-title>Quantification of retinal nerve fiber layer thickness in the normal subjects using optical coherence tomography</article-title>
      <source>J Korean Ophthalmol Soc</source>
      <year>1999</year>
      <volume>40</volume>
      <fpage>2804</fpage>
      <lpage>2815</lpage>
    </element-citation>
  </ref>

  <ref id="B11">
    <label>11</label>
    <element-citation publication-type="journal">
      <person-group person-group-type="author">
        <name>
          <surname>Savini</surname>
          <given-names>G</given-names>
        </name>
        <name>
          <surname>Carbonelli</surname>
          <given-names>M</given-names>
        </name>
        <name>
          <surname>Barboni</surname>
          <given-names>P</given-names>
        </name>
      </person-group>
      <article-title>Retinal nerve fiber layer thickness measurement by Fourier-domain optical coherence tomography: a comparison between cirrus-HD OCT and RTVue in healthy eyes</article-title>
      <source>J Glaucoma</source>
      <year>2010</year>
      <volume>19</volume>
      <fpage>369</fpage>
      <lpage>372</lpage>
    </element-citation>
  </ref>

  <ref id="B12">
    <label>12</label>
    <element-citation publication-type="journal">
      <person-group person-group-type="author">
        <name>
          <surname>Chang</surname>
          <given-names>RT</given-names>
        </name>
        <name>
          <surname>Knight</surname>
          <given-names>OJ</given-names>
        </name>
        <name>
          <surname>Feuer</surname>
          <given-names>WJ</given-names>
        </name>
        <name>
          <surname>Budenz</surname>
          <given-names>DL</given-names>
        </name>
      </person-group>
      <article-title>Sensitivity and specificity of time-domain versus spectral-domain optical coherence tomography in diagnosing early to moderate glaucoma</article-title>
      <source>Ophthalmology</source>
      <year>2009</year>
      <volume>116</volume>
      <fpage>2294</fpage>
      <lpage>2299</lpage>
    </element-citation>
  </ref>

  <ref id="B13">
    <label>13</label>
    <element-citation publication-type="journal">
      <person-group person-group-type="author">
        <name>
          <surname>Patel</surname>
          <given-names>NB</given-names>
        </name>
        <name>
          <surname>Wheat</surname>
          <given-names>JL</given-names>
        </name>
        <name>
          <surname>Rodriguez</surname>
          <given-names>A</given-names>
        </name>
        <etal/>
      </person-group>
      <article-title>Agreement between retinal nerve fiber layer measures from Spectralis and Cirrus spectral domain OCT</article-title>
      <source>Optom Vis Sci</source>
      <year>2012</year>
      <volume>89</volume>
      <fpage>E652</fpage>
      <lpage>E666</lpage>
    </element-citation>
  </ref>

  <ref id="B14">
    <label>14</label>
    <element-citation publication-type="journal">
      <person-group person-group-type="author">
        <name>
          <surname>Knight</surname>
          <given-names>OJ</given-names>
        </name>
        <name>
          <surname>Chang</surname>
          <given-names>RT</given-names>
        </name>
        <name>
          <surname>Feuer</surname>
          <given-names>WJ</given-names>
        </name>
        <name>
          <surname>Budenz</surname>
          <given-names>DL</given-names>
        </name>
      </person-group>
      <article-title>Comparison of retinal nerve fiber layer measurements using time domain and spectral domain optical coherent tomography</article-title>
      <source>Ophthalmology</source>
      <year>2009</year>
      <volume>116</volume>
      <fpage>1271</fpage>
      <lpage>1277</lpage>
    </element-citation>
  </ref>

  <ref id="B15">
    <label>15</label>
    <element-citation publication-type="journal">
      <person-group person-group-type="author">
        <name>
          <surname>Bayraktar</surname>
          <given-names>S</given-names>
        </name>
        <name>
          <surname>Bayraktar</surname>
          <given-names>Z</given-names>
        </name>
        <name>
          <surname>Yilmaz</surname>
          <given-names>OF</given-names>
        </name>
      </person-group>
      <article-title>Influence of scan radius correction for ocular magnification and relationship between scan radius with retinal nerve fiber layer thickness measured by optical coherence tomography</article-title>
      <source>J Glaucoma</source>
      <year>2001</year>
      <volume>10</volume>
      <fpage>163</fpage>
      <lpage>169</lpage>
    </element-citation>
  </ref>

  <ref id="B16">
    <label>16</label>
    <element-citation publication-type="journal">
      <person-group person-group-type="author">
        <name>
          <surname>Song</surname>
          <given-names>TG</given-names>
        </name>
        <name>
          <surname>Yoo</surname>
          <given-names>YC</given-names>
        </name>
        <name>
          <surname>Lee</surname>
          <given-names>HB</given-names>
        </name>
      </person-group>
      <article-title>Quantitative analysis of retinal nerve fiber layer thickness profile in myopic eyes</article-title>
      <source>J Korean Ophthalmol Soc</source>
      <year>2009</year>
      <volume>50</volume>
      <fpage>1840</fpage>
      <lpage>1846</lpage>
    </element-citation>
  </ref>

  <ref id="B17">
    <label>17</label>
    <element-citation publication-type="journal">
      <person-group person-group-type="author">
        <name>
          <surname>Leung</surname>
          <given-names>CK</given-names>
        </name>
        <name>
          <surname>Mohamed</surname>
          <given-names>S</given-names>
        </name>
        <name>
          <surname>Leung</surname>
          <given-names>KS</given-names>
        </name>
        <etal/>
      </person-group>
      <article-title>Retinal nerve fiber layer measurements in myopia: An optical coherence tomography study</article-title>
      <source>Invest Ophthalmol Vis Sci</source>
      <year>2006</year>
      <volume>47</volume>
      <fpage>5171</fpage>
      <lpage>5176</lpage>
    </element-citation>
  </ref>
</ref-list>

</back>

<floats-group>

<fig position="float" id="F1">
<label>Figure 1</label>
<caption>
<title>Scatterplot of mean and 4 quadrant retinal nerve fiver layer (RNFL) thickness according to age. (A-E) All graphs represent a decreasing tendency of thickness by aging. CI = confidence interval.</title>
</caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="jkos-58-1160-g001"></graphic>
</fig>

<fig position="float" id="F2">
<label>Figure 2</label>
<caption>
<title>Distribution of Retinal nerve fiber layer (RNFL) thickness according to group. This schimatized graph represent the it is thinner in the older age group.</title>
</caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="jkos-58-1160-g002"></graphic>
</fig>

<fig position="float" id="F3">
<label>Figure 3</label>
<caption>
<title>Scatterplot of 12 clock-hour sectors of retinal nerve fiber layer thickness (RNFL) according to age. (A-L) All graphs represent a decreasing tendency of thickness by aging. CI = confidence interval.</title>
</caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="jkos-58-1160-g003"></graphic>
</fig>

<fig position="float" id="F4">
<label>Figure 4</label>
<caption>
<title>Distribution of retinal nerve fiber layer thickness (RNFL) thickness according to age (group by 10's). This schimatized graph represent the it is thinner in the older age group.</title>
</caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="jkos-58-1160-g004"></graphic>
</fig>

<table-wrap position="float" id="T1">
<label>Table 1</label>
<caption>
  <title>Subject distribution by age group</title>
</caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="jkos-58-1160-i001"></graphic>
<table-wrap-foot>
<fn>
  <p>Values are presented as mean &#x00B1; SD unless otherwise indicated.</p>
  <p>M = male; F = female; BCVA = best corrected visual acuity.</p>
  <p><sup>*</sup>One-way analysis of variance (ANOVA).</p>
</fn>
</table-wrap-foot>
</table-wrap>

<table-wrap position="float" id="T2">
<label>Table 2</label>
<caption>
  <title>Distribution of RNFL thickness in the 4 quadrants and 12 clock-hour sectors</title>
</caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="jkos-58-1160-i002"></graphic>
<table-wrap-foot>
<fn>
<p>Values are presented as mean &#x00B1; SD unless otherwise indicated.</p>
<p>RNFL = retinal nerve fiber layer; S = superior; T = temporal; N = nasal; I = inferior.</p>
</fn>
</table-wrap-foot>
</table-wrap>

<table-wrap position="float" id="T3">
<label>Table 3</label>
<caption>
<title>Slopes and annual rates of decrease for mean, 4 quadrants, and 12 clock-hour sectors RNFL thickness</title>
</caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="jkos-58-1160-i003"></graphic>
<table-wrap-foot>
<fn>
<p>RNFL = retinal nerve fiber layer; CI = confidence interval; S = superior; T = temporal; N = nasal; I = inferior.</p>
</fn>
</table-wrap-foot>
</table-wrap>

<table-wrap position="float" id="T4">
<label>Table 4</label>
<caption>
<title>Distribution of RNFL thickness in the 4 quadrants and 12 clock-hour sectors (Group by 10's)</title>
</caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="jkos-58-1160-i004"></graphic>
<table-wrap-foot>
<fn>
<p>Values are presented as mean &#x00B1; SD unless otherwise indicated. RNFL = retinal nerve fiber layer; T = temporal; S = superior; N = nasal; I = inferior.</p>
</fn>
</table-wrap-foot>
</table-wrap>

<table-wrap position="float" id="T5">
<label>Table 5</label>
<caption>
  <title>Comparison of RNFL thickness with other research in Korea</title>
</caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="jkos-58-1160-i005"></graphic>
<table-wrap-foot>
<fn>
  <p>Values are presented as mean &#x00B1; SD unless otherwise indicated.</p>
  <p>RNFL = retinal nerve fiber layer; n = number of eyes.</p>
  <p><sup>*</sup>Unpaired <italic>t</italic>-test.</p>
</fn>
</table-wrap-foot>
</table-wrap>

</floats-group>

</article>