Journal List > Hip Pelvis > v.25(1) > 1082008

Cho and Chang: History of the Artificial Hip Joint

Abstract

For several centuries, orthopaedic surgeons have been given the task of managing the pain, limp, and gait disturbance that develop in association with various trauma and diseases of the hip joint. Progress has been made in development of surgical methods for the hip joint, and a recent concept was determined by introduction of the 'Clean Air Operating Enclosure' system and 'low frictional arthroplasty' in total hip arthroplasty (THA) by John Charnley, in 1960. THA has been performed as an exclusive method for hip joint reconstruction. We report on understanding of the current status from the past, present, and future trends with an introduction of the prior method of THA and a discussion of the history.

Figures and Tables

Fig. 1
Philip W. Wiles designed the first total hip arthroplasty made of stainless steel.
hp-25-6-g001
Fig. 2
Original Charnley total hip prosthesis with Teflon cup.
hp-25-6-g002
Fig. 3
Large head in total hip arthroplasty.
hp-25-6-g003

References

1. Charnley JA. A clean-air operating enclosure. Br J Surg. 1964. 51:202–205.
crossref
2. Crowninshield RD, Maloney WJ, Wentz DH, Humphrey SM, Blanchard CR. Biomechanics of large femoral heads: what they do and don't do. Clin Orthop Relat Res. 2004. (429):102–107.
3. Amstutz HC, Clarke IC. Amstutz HC, editor. Evolution of hip arthroplasty. Hip arthroplasty. 1991. 1st ed. New York: Churchill Livingstone;1–14.
4. Eftekhar NS, Demarest RJ. Eftekhar NS, Demarest RJ, editors. History and development. Total hip arthroplasty. 1993. St. Louis: Mosby;3–14.
5. Radcliffe SN, Geary NP. 46-year survival of a Smith-Petersen mold arthroplasty. J Arthroplasty. 1997. 12:584–585.
crossref
6. Aufranc OE. Constructive hip surgery with the vitallium mold; a report on 1,000 cases of arthroplasty of the hip over a fifteen-year period. J Bone Joint Surg Am. 1957. 39-A:237–248. passim.
7. Charnley J, Cupic Z. The nine and ten year results of low-friction arthroplasty of the hip. Clin Orthop Relat Res. 1973. (95):9–25.
8. Weller S. "Cemented or cementless fixation?" an individual decision in total hip arthroplasty. International orthop 1, Implant special. 1977. Springer.
9. McMinn D, Treacy R, Lin K, Pynsent P. Metal on metal surface replacement of the hip. Experience of the McMinn prosthesis. Clin Orthop Relat Res. 1996. (329):Suppl. S89–S98.
10. Campbell P, Ebramzadeh E, Nelson S, Takamura K, De Smet K, Amstutz HC. Histological features of pseudotumor-like tissues from metal-on-metal hips. Clin Orthop Relat Res. 2010. 468:2321–2327.
crossref
11. Watters TS, Cardona DM, Menon KS, Vinson EN, Bolognesi MP, Dodd LG. Aseptic lymphocyte-dominated vasculitis-associated lesion: a clinicopathologic review of an underrecognized cause of prosthetic failure. Am J Clin Pathol. 2010. 134:886–893.
crossref
12. Walter WL, Yeung E, Esposito C. A review of squeaking hips. J Am Acad Orthop Surg. 2010. 18:319–326.
crossref
13. Bargar W. Robotic hip surgery and current development with the ROBODOC system. Navigation and robotics in total joint and spine surgery. 2004. Berlin: Springer;119–122.
crossref
TOOLS
Similar articles