Optimization of the Contrast Mixture Ratio for Simultaneous Direct MR and CT Arthrography: an in Vitro Study
Ja-Young Choi, MD,1Heung Sik Kang, MD,2Sung Hwan Hong, MD,1Joon Woo Lee, MD,2Na Ra Kim, MD,1Woo Sun Jun, MD,1Sung Gyu Moon, MD,1
and Jung-Ah Choi, MD2
1Department of Radiology and Institute of Radiation Medicine, Seoul National University College of Medicine, Seoul 110-744, Korea.
2Department of Radiology, Seoul National University Bundang Hospital, Gyeongi-do 463-707, Korea.
Address reprint requests to: Heung Sik Kang, MD, Department of Radiology, Seoul National University Bundang Hospital, 300 Gumi-dong, Bundag-gu, Seongnam-si, Gyeonggi-do 463-707, Korea. Tel. (8231)787-7609, Fax. (8231)787-4011, Email: kanghs@radcom.snu.ac.kr
Received February 15, 2008; Accepted July 09, 2008.
Abstract
Objective
This study was designed to determine the optimal mixture ratio of gadolinium and iodinated contrast agent for simultaneous direct MR arthrography and CT arthrography.
Materials and Methods
An in vitro study was performed utilizing mixtures of gadolinium at six different concentrations (0.625, 1.25, 2.5, 5.0, 10 and 20 mmol/L) and iodinated contrast agent at seven different concentrations (0, 12.5, 25, 37.5, 50, 75 and 92-99.9%). These mixtures were placed in tissue culture plates, and were then imaged with CT and MR (with T1-weighted sequences, proton-density sequences and T2-weighted sequences). CT numbers and signal intensities were measured. Pearson's correlation coefficients were used to assess the correlations between the gadolinium/iodinated contrast agent mixtures and the CT numbers/MR signal intensities. Scatter diagrams were plotted for all gadolinium/iodinated contrast agent combinations and two radiologists in consensus identified the mixtures that yielded the optimal CT numbers and MR signal intensities.
Results
The CT numbers showed significant correlation with iodinated contrast concentrations (r = 0.976, p < 0.001), whereas the signal intensities as measured on MR images showed a significant correlation with both gadolinium and iodinated contrast agent concentrations (r = -484 to -0.719, p < 0.001). A review of the CT and MR images, graphs, and scatter diagram of 42 combinations of the contrast agent showed that a concentration of 1.25 mmol/L gadolinium and 25% iodinated contrast agent was the best combination for simultaneous CT and MR imaging.
Conclusion
A mixture of 1.25 mmol/L gadolinium and 25% iodinated contrast agent was found to be optimal for simultaneous direct MR arthrography and CT arthrography.
Czerny C,Hofmann S,Neuhold A,Tschauner C,Engel A,Recht MP,et al. Lesions of the acetabular labrum: accuracy of MR imaging and MR arthrography in detection and staging. Radiology 1996;200:225–230.
3.
Montgomery DD,Morrison WB,Schweitzer ME,Weishaupt D,Dougherty L. Effects of iodinated contrast and field strength on gadolinium enhancement: implications for direct MR arthrography. J Magn Reson Imaging 2002;15:334–343.
4.
Sciulli RL,Boutin RD,Brown RR,Nguyen KD,Muhle C,Lektrakul N,et al. Evaluation of the postoperative meniscus of the knee: a study comparing conventional arthrography, conventional MR imaging, MR arthrography with iodinated contrast material, and MR arthrography with gadolinium-based contrast material. Skeletal Radiol 1999;28:508–514.
5.
Zanetti M,Hodler J. Contrast media in MR arthrography of the glenohumeral joint: intra-articular gadopentetate vs saline: preliminary results. Eur Radiol 1997;7:498–502.
6.
Farber JM. CT arthrography and postoperative musculoskeletal imaging with multichannel computed tomography. Semin Musculoskelet Radiol 2004;8:157–166.
7.
Schmid MR,Pfirrmann CW,Hodler J,Vienne P,Zanetti M. Cartilage lesions in the ankle joint: comparison of MR arthrography and CT arthrography. Skeletal Radiol 2003;32:259–265.
8.
Vande Berg BC,Lecouvet FE,Poilvache P,Jamart J,Materne R,Lengele B,et al. Assessment of knee cartilage in cadavers with dual-detector spiral CT arthrography and MR imaging. Radiology 2002;222:430–436.
9.
Lecouvet FE,Simoni P,Koutaissoff S,Vande Berg BC,Malghem J,Dubuc JE. Multidetector spiral CT arthrography of the shoulder. Clinical applications and limits, with MR arthrography and arthroscopic correlations. Eur J Radiol 2008;68:120–136.
10.
Schmid MR,Schertler T,Pfirrmann CW,Saupe N,Manestar M,Wildermuth S,et al. Interosseous ligament tears of the wrist: comparison of multi-detector row CT arthrography and MR imaging. Radiology 2005;237:1008–1013.
11.
Kopka L,Funke M,Fischer U,Keating D,Oestmann J,Grabbe E. MR arthrography of the shoulder with gadopentetate dimeglumine: influence of concentration, iodinated contrast material, and time on signal intensity. AJR Am J Roentgenol 1994;163:621–623.
12.
Masi JN,Newitt D,Sell CA,Daldrup-Link H,Steinbach L,Majumdar S,et al. Optimization of gadodiamide concentration for MR arthrography at 3 T. AJR Am J Roentgenol 2005;184:1754–1761.
Engel A. Magnetic resonance knee arthrography. Enhanced contrast by gadolinium complex in the rabbit and in humans. Acta Orthop Scand Suppl 1990;240:1–57.
15.
Jinkins JR,Robinson JW,Sisk L,Fullerton GD,Williams RF. Proton relaxation enhancement associated with iodinated contrast agents in MR imaging of the CNS. AJNR Am J Neuroradiol 1992;13:19–27.